Calyenty Service and Support 0034 972 660 467
Why take out a Calyenty Maintenance
Contract?
1. Extend the life of your pool heater.
2. Ensure optimum efficiency to provide the maximum
heat from your system in the most economical way.
3. Pre-empt any periods where your pool is not heated.
4. More economical than post-failure fix or repair.
5. Prevent damaging your heater by running your system
with a pool or heat pump problem which a service call
will identify early.
6. Scheduled service calls so no waiting for an eventual
expensive repair.
Remember, a heat pump heating breakdown can range from
being an inconvenience to an outright disaster, (villa
full of friends expecting a warm pool!) so make sure you’re
going to get the best service, whether it’s as part of
a heat pump service contract or as stand- alone heat pump
breakdown cover.
Calyenty cover all Calyenty heat pumps.
When to take out a Calyenty Maintenance
Contract?
You can take out a Calyenty maintenance
contract on day one that you purchase your RBH heat pump
pool heating system. If you do this we will do your first
service call for free. If you choose you can take out
a maintenance contract at any time, just contact our sales
team on 0034972660467
CALYENTY SWIMMING POOL HEAT PUMPS 20 Point
Service Plan
Operation Operación
Where × please report at bottom of this form.
Cuando × por favor informe en la parte inferior de este formulario.
√ × Reading
1 Check filter basket on circulation pump. All systems must be
switched off and taps set correctly to perform this check.
Compruebe el filtro en la bomba de circulación. Todos los sistemas
deben estar apagados y grifos configurado correctamente para realizar
esta verificación. ---------
2 Check drain-down status is set correctly.
Compruebe el estado de drenaje está configurado correctamente.
---------
3 Check by-pass is set correctly.
Compruebe el estado de bi-pass está configurado correctamente.
---------
4 Check gas pressure reading while unit is switched off – take
reading from R407 green gauge.
Compruebe la presión de gas mientras que la unidad está apagada
- tomar la lectura de medidor R407 verde.
--- ---
5 Check power supply to heat pump – must only function with filter
pump on. Must turn filter pump off to confirm this check. Confirm
heat pump and control panel lose power immediately the circulation
pump is switched OFF.
Compruebe la alimentación de la bomba de calor - sólo debe funcionar
con la bomba de filtro. Debe activar el filtro de la bomba fuera
para confirmar esta comprobación. Confirmar la bomba de calor
y panel de control de perder el poder inmediatamente la bomba
de circulación está apagado. ---------
6 Switch systems on and check controller
screen for error codes.
Enciende y comprobar pantalla del controlador para los códigos
de error.
7 Check mode setting corresponds with manual.
Compruebe el modo de ajuste corresponde con el manual.
8 Record air temperature.
Registro de la temperatura del aire. --- ---
9
Record water temperature:
from controller.
Toma una nota del temperatura actual del agua del controlador.
From independent thermometer
10 Record water set temperature from controller.
Toma una nota del temperatura pedido del agua del controlador.
--- ---
11 Check screen shows E7 (version 1.0) E3 (versions 2.0 plus)
when no water flows through machine, use water by-pass to perform
this check.
La pantalla de verificación indica E7 (versión 1.0) E3 (versiones
2.0 más) cuando el agua no fluye a través de la máquina, el
uso del agua de by-pass para realizar esta verificación. State
E7/E3
12 Check gas pressure and record reading while unit is on and
running, take reading after five minutes.
Compruebe la presión del gas mientras que la unidad está encendida
y en funcionamiento, después de cinco minutos. --- ---
13 Blow clean sides of heat pump (evaporator coil).
limpias los lados de la bomba de calor (serpentín del evaporador).
Con aire presión ---------
14 Remove fan housing from top of machine.
Eliminar caja del ventilador de la parte superior de la máquina.
---------
15 Vacuum clean all debris from inside of the unit.
Aspiradora para limpiar todos los desechos desde el interior
de la unidad. ---------
16 Check drainage hole is free of any obstruction where drip
tray is fitted.
Compruebe agujero de drenaje está libre de cualquier obstrucción
en base de inox esté instalado. ---------
17 Refit fan ensure cable is out of reach of fan blades after
all internal cleaning and part replacement is complete.
Vuelva a colocar garantizar cable del ventilador está fuera
del alcance de las aspas del ventilador, después de todo la
limpieza interna y sustitución de piezas es completa. ----------
18 Check timer on circulation pump is set correctly.
Compruebe reloj en la bomba de circulación está establecido
correctamente.
19 Check space around and above machine for sufficient air flow,
remove any obstructions which reduce space to anything other
than recommended in the user manual.
Compruebe el espacio alrededor y por encima de la máquina para
el flujo de aire suficiente, eliminar cualquier obstáculo que
reduce el espacio para otra cosa que no se recomienda en el
manual de usuario.
20 Ask the client how he wishes to leave the machine
(i.e. running or drained down)
Pregunte al cliente cómo quiere deja de la máquina
(es decir, marcha o drenaje)
* All Calyenty engineers are monitored and approved officially
registered and qualified to work on your particular system.
Discount anyone who cannot show you Spanish lampista accreditation
credentials reasonably promptly or who resists attempts to see
them.
* Emergency line open 24 hours a day, every day of the year.
You never know when disaster might strike.
* Likewise, 24 call-out in genuine emergencies should be available.
* Guarantees on all repairs.
* No limit on number of call-outs.
* Free or discounted parts or labour included with repairs
* Cashback or discount on a new heat pump if existing system
fails entirely.
What Do I need to do?
Call us today with your machine serial number, date of purchase,
name of dealer from where heat pump was purchased, NIE, address,
telephone number plus telephone number of your key holder or
person who that can give us access to your pool house. 195.00
euros SWIFTBIC and IBAN of Spanish bank account. Companies reg
company name with any VAT number.
swimming pool heat pump-automatic pool covers - fibreglass swimming